Fanox offers complete solutions providing, not only highest quality electronic protection relays, also required current transformers to get protection and measuring capability. Based on relays, different types of current transformers can be used, adapted to customer requirements, both mechanical and functional.

Regarding technical features, all required values that define a CT, as transformation ratio, burden, accuracy class, protection class, frequency, isolation level, ….are adapted to be completely compatible with Fanox electronic Relays.

Furthermore, in case customer has mechanical limitations or a specific CT Type is required, we can study customized production.

Protection & Measurement for Medium Voltage

Protection & Self-powered Transformer for MV – CT-MTP

  • Current transformer for indoor service and without primary coll
  • With one secondary for protection /1 or /5
  • Valid for protection or protection/self-power
  • Standard IEC 60044-1

Protection & Measurement for MV – CT-MTP

  • Up to 1200 A of primary current
  • Transformer ratio 1000/1
  • Terminal cover, poka yoke xing base
  • Certicate model

Taped Current Transformers for SIA-B Specifics CT’s  Relays – CT-MTP Taped

The low power switchgear CT’s are specially designed for application in Medium Voltage installations as RMU’s. This PVC TAPED transformer is cost effective and very reliable. It is designed for dynamic loads and appicable for the CT powered relays.

Epoxy resin Current Transformers for SIA-B Dual & Self Powered Relays CT-MTP Epoxy

The low power switchgear CT’s are specially designed for application in Medium Voltage installations as RMU’s. This EPOXY RESIN transformer is cost effective and very reliable. It is designed for dynamic loads and appicable for the CT powered relays.

Electric Energy Measurement for Remote Management in Low Voltage

CT 80II / CT4II
Extended Current Transformers

One of the main advantages of this transformer is its compact size, with an inner diameter of 80 mms and an external size of 116 x 105mm

CT80 ABR
Split Core Current Transformer

Split core current transformers facilitate assembly without disconnection in existing installations. Transformers with a compact size to save space.

CT80II ABR
Split Core Current Transformer

Split core transformers. you do not need shutdown existing installations, enable transformer measure current without needing to interrupt the supply, making the assembling easier

CT60II EXT
Current Transformer for OUTDOOR

Designed for outdoor installation. Transformer ratio 400/5Compact size With core and cable incorporated, spliceless

Protection & Measurement for Low Voltage

CT50
Toroidal Current Transformer

  • Provided burden up to 15 VA.
  • Transformer ratio …/5.
  • Fixing base included.

CT 20-30-50-70-90
Standard Current Transformers

  • Up to 3200 A of primary current.
  • Transformers ratio …/5.
  • Seable plastic cover, metal brackets for fitting, bus-bar holders and DIN rail mounting accessories included.
  • Standards: IEC 60044-1, BS 2627

CT20N
Narrow Profile Current Transformer

  • Protection and measurement CT for low voltaje.
  • Up to 1200A of primay current.
  • Transformer ratio …/5.

Earth leakage Protection & Measurement for Low Voltage

Toroidal Transformers CT1/CTD1

  • To be used with ELR-B, ELR-3C, D30 and DM30 relays.
  • The transformer and relay assembly sensitivity is fixed by the relay.
  • The toroidal transformer CTD-1/28 is specifically designed for DIN rail mounting.

Current Limiting & Filtering

Current Limitant Input Reactor CLR

  • Nominal Current: 250 A
  • Linearity without saturation until: 1.5 x In
  • Protection against indirect contacts

Voltage Transformation for Low Voltage

Potential Transformer Encapsulated PT

  • Transformer designed in double cell, encapsulated in poliuretane.
  • Dielectrical strength 3000 Vac 50 Hz between Primary and Secondary
  • Possibility of soldering over PCB